EN

1.jpg 2.jpg

AF2000 Electromagnetic Flowmeter

About AF2000 Electromagnetic Flowmeter

The electromagnetic flowmeter (EMF) can be used to accurately measure the flow of liquid, pulp, slurry and ore pulp with conductivity greater than 5 μS/cm. The AF2000 integrated EMF is a flow measurement system in which the sensor and transducer are designed into one, while the AF2000 Seperated EMF is the sensor and transducer installed separately.

AF2000(1).png

Product Features

  • icon08.svg
    High accuracy
    • 0.5% reading

  • icon09.svg
    Diverse communication modes
    • 4-20mA+HART+Modbus+Contact switch (both active and passive outputs can be selected)

  • icon10.svg
    Various process connections
    • Flanges conforms to GB+ASME/ANSI+GOST+JIS+EN

  • icon11.svg
    Wide range of electrodes
    • 316L, HC, Platinum-iridium alloy, Tantalum, Titanium, etc

  • icon12.svg
    Multiple lining options
    • PTFE, PFA, F46, Chloroprene rubber, etc.

  • icon13.svg
    IP rating
    • IP67 + IP68 Submersible split-type  (Sensor end)

  • icon14.svg
    • Bidirectional measurement capability

  • icon15.svg
    • Self-diagnostic function

  • icon16.svg
    Self-diagnostic function
    • Wide voltage range 85-253V AC/16.8-26.4V AC/16.8-31.2V DC

Technical Parameters

  • Sensor

  • Type

    Flange type & Clamp type

  • Accuracy

    0.5% indication

  • Diameter (mm)

    DN10-DN1000 (Clamp type DN10-DN100)

  • Pressure Rating (MPa)

    1.0-4.0 (by diameter)

  • Lining Material

    Rubber, PTFE, PFA, F46, Others according to the order requirements

  • Conductivity

    >5μS/cm

  • Electrode

    Stainless steel 0Cr18Ni12Mo2Ti, Hastelloy B2/C4, platinum-iridium, tantalum, titanium

  • IP Grade

    IP67

  • Fluid Temperature

    -25~+130° C (rubber lining ≤ 65° C)

  • Transducer

  • Power Supply

    85-253V AC/16.8-26.4V AC/16.8-31.2V DC

  • Current Output

    0/2-10mA, 0-5mA, 0/4-20mA, 0/4-10/12-20mA

  • Pulse Output

    Active 24 V DC pulse or passive optocoupler

  • Data Transmission

    RS485 (optional), HART protocol

  • Forward/Reverse Flow

    Positive signal optocoupler output

  • Self-test

    Available

  • Field Indication/Accumulation

    Available

  • Housing Material

    Cast aluminum and carbon steel housing(DE43F/DE43W Cast aluminum (standard))

a0_bg01.png